Reinforced fiberglass enclosures RizurBox-C-U with horizontal opening and all-around access to equipment

Fiberglass enclosures RizurBox-C-U with horizontal opening allow access to equipment from all sides thanks to the top part of the enclosure that can be opened or removed completely.

Enclosures are used in all branches of the industry where there’s a need for heating and protecting the equipment. RizurBox-C-U series includes design variants with various dimensional specifications which allows the customer to get the enclosure that can protect network devices, flow meters, pressure sensors, level meters, and other devices.


RizurBox-C-U enclosures are used in explosion-hazardous and general use industrial areas, in both outdoor and indoor locations, for creating and maintaining the temperature required for the equipment to work properly.

RizurBox-C-U are used for equipment protection against:

  • freezing

  • moisture and ice built-up

  • combustion

  • aggressive chemical media

  • dust

  • ultraviolet radiation

  • mechanical damages

  • unauthorized access and theft

The devices and equipment located in the enclosure can be accessed from all the sides because the RizurBox-C-U series design variants can have several mounting elements which allow the top part to be opened or removed completely.

Enclosures are manufactured according to TR--3442-001-12189681-2014. RizurBox-C-U have an antistatic surface and a multi-layer housing made of glass-reinforced plastic and inflammable unsaturated polyester resin. Thermal insulation between the inside and outside surface is provided by the polyurethane foam. All enclosures are made from inflammable materials and have a fire safety certificate № NSOPB.RU.PR004.N.00026.

Reinforced fiberglass enclosure RizurBox-C-U is operated at ambient air temperature from - 60 °С to + 70°С. Inside the enclosure, depending on the heating system used, the maintained temperature can range from -40°С to +50°С.

Подробнее Скрыть

Installation area
Explosion-hazardous areas V-1a and V-1d, acc. to Electrical installation code (PUE), Ch. 7.3
Ingress protection
IP54 acc. to GOST 14254-96
IP65 acc. to GOST 14254-96 (on request)
IP66 acc. to GOST 14254-96 (on request)
Surface resistance (antistatic)
under 109 Ohm
Temperature maintained inside (depending on the type of heating and the heater's parameters) 
-40°С ... +50°С
Operating temperature
-60°С ... +70°С
-70°С ... +70°С
(with additional heat insulation K-Flex)
Resistivity
to oil products
to chemical environments
to UV radiation
Wall thickness
20 ... 40 mm (depending on the enclosure's design variant)
Fiberglass thickness
2 ... 4 mm (depending on the enclosure's design variant)
Thermal conductivity
0,03 W/(m*K)
Fitting materials (locks, hinges)
stainless steel
Explosion protection marking for enclosures with water/steam heating:
- water/steam heating is under 195 °C
- water/steam heating is under 135 °C
- water/steam heating is under 95 °C
- water/steam heating is under 80 °C
Ex II Gb IIC T3 X II Gb IIC T3 X
Ex II Gb IIC T4 X II Gb IIC T4 X
Ex II Gb IIC T5 X II Gb IIC T5 X
Ex II Gb IIC T6 X II Gb IIC T6 X
Explosion protection marking for enclosures without heating:
- without heating
Ex II Gb IIC II Gb IIC
Colour RAL 7035 light-grey
any colour (on request)
Warranty period 12 months
24/36 months (on request)
Average operation time over 15 years


Design variant Dimensions H x W x D, mm
RizurBox-C-U-1 435    х    415   х    350
RizurBox-C-U-2 435    х    415   х    500
RizurBox-C-U-3
1105  х    960   х   1030
 


0