Turbine type flow meter RIZUR-DOT

Turbine type flow meter RIZUR-DOT consists of a spiroid turbine rotor, mounted on two tungsten carbide bearings, with the rotor itself, manufactured from hard ferritic stainless steel with a grade compatible with the measured liquid, is positioned fully inside the housing made of non-magnetic stainless steel.

Description

Turbine type flow meter RIZUR-DOT consists of a spiroid turbine rotor, mounted on two tungsten carbide bearings, with the rotor itself, manufactured from hard ferritic stainless steel with a grade compatible with the measured liquid, is positioned fully inside the housing made of non-magnetic stainless steel. The housing has an inductive coil with a magnetic core located in close proximity to the end of the rotor's blades which together with the blades make a magnetic circuit (pic.1).

 Rotor's movement changes the magnetic circuit resistance and the changes in the magnetic flow create small voltage in the reel with its frequency directly proportional to the rotor speed and, thus, proportional to the rate of volume flow (flow rate) of the measured liquid

Increase in media viscosity limits the range of the linear flow rate, the lower limit of the flow rate should increase with increase of the liquid’s viscosity with the max. viscosity at 10 mm2/sec. In order to calculate the low level of the linear flow the following should be done: multiply 0.7 by the square root of the measured liquid viscosity in mm²/sec, multiplied by the normal minimum flow rate. For example, if the normal flow range is 10 ~ 100 l/min, then with a viscosity of 5 mm²/s, the minimum flow rate should be 15.65 l/min.

RizurDot1.PNG

Turbine type flow meter is a high-precision, reliable device that is used for flow measurement of clean liquids with low viscosity. RIZUR-DOT model is manufactured from stainless steel with tungsten carbide bearings ensures long service life for operation with a wide range of aggressive and non-lubricating fluids in the petrochemical industry and general purpose industrial grade usage.

Standard version of the device has a frequency output (mV sinusoidal waves) or a preamplifier output of the square waves (4...20 mA impulses). Turbine type flow meter has a MS terminal for the impulse signal output. It can also be equipped with the integral devices for the operating in adverse conditions that can amplify the signals' transmission range or connect to the accessory instruments that require a corresponding input signal. The devices can be, for example, a Z1 adder, a Z3/Z5 flow integrator or a batch meter B1.

If your flow meter is installed together with some other device, please, use the corresponding manual for information of details and output functions.

Application areas

  • Chemicals
  • Medical products
  • Different types of fuel
  • Deionized water
  • Fuel additives

Technical specifications

Measuring range: 0.11 - 1.1 m3/h … 13.5 - 135 m3/h for water (other on request)
Viscosity range: low viscosity
Linearity: ±0.15 % ... ±0.5 % of the readings
Max. pressure: 250 bar;
Max. temperature: 240 °C
Process connection: G ½…G 2 male thread, ½" NP T…2" NPT male thread, DIN-flanges DN 15…DN 150 (larger - on request), ANSI flanges with sizes ½"... 6" (larger - on request)
Material: stainless steel, carbon steel
Output signal: pulses, LCD display, 4...20mA, batching, totalisi


Electronic modules with LCD-display

Model

-Z1

.Z3

.Z5

..В1

Function

dual totaliser

rate totalizer

rate totalizer

batch controller

Power source

Battery power

yes

yes

yes

no

External power source

8-24Vdc

8-24Vdc

8-24Vdc

12-24Vdc

LCD display

- line 1 /q-ty of digits

7.5 mm/5

9 mm/8

17 mm/6

9 mm/8

- line 2/q-ty of digits

3.6 mm/8

-

7 mm/8

-

selectable units

yes

yes

yes

yes

decimal point

yes

yes

yes

yes

subscripts displayed

yes

yes

yes

yes

accumulative total

yes

yes

yes

yes

resettable total

yes

yes

yes

no

linearisation

no

yes

no

no

rate display

no

yes

yes

no

backlighting

no

no

yes

no

Input type

Battery-powered sensors

See ZOD technnical specifications table 

Sensors with line supply

See ZOD technnical specifications table 

Output types

4-20 mА (750 Ohm)

no

yes

no

no

high/low flow alarm 

no

NPN/PNP

NPN

no

batch end&control

no

no

no

NPN/PNP

pulse outputs

NPN/PNP

NPN/PNP

NPN

NPN/PNP

2 х SPDT relays

no

по заказу*

no

по заказу*

Installation

IP 66/67

yes

yes

yes

yes

cable glands

1 х cable gland (with intrumentation) 

2 х cable glands (at a distance)

3хМ20

3хМ16  

3хМ20

internal protection (optional)

no yes     no no

mounting

meter mount, wall, pipe or panel mounting

temperature range

-20... +80 °С (Optional: -20... +120 °С)

 *replaces solid state outputs

Flange connection

Model (mm)
RIZUR-DOT-XX05... 127
RIZUR-DOT-XX10...
127
RIZUR-DOT-XX15... 127
RIZUR-DOT-XX20... 140
RIZUR-DOT-XX25... 152
RIZUR-DOT-XX30... 178
RIZUR-DOT-XX35... 197
RIZUR-DOT-XX40... 254
RIZUR-DOT-XX45... 356
RIZUR-DOT-XX50... 368

Pulse output (nominal)

Model Pulses/litre  
RIZUR-DOT-XX05... 4000
RIZUR-DOT-XX10... 1700
RIZUR-DOT-XX15... 1100
RIZUR-DOT-XX20... 400
RIZUR-DOT-XX25... 180
RIZUR-DOT-XX30... 60
RIZUR-DOT-XX35... 24
RIZUR-DOT-XX40... 15
RIZUR-DOT-XX45... 6.6
RIZUR-DOT-XX50... 2.3

Thread connection

Model B(mm) С (mm)
RIZUR-DOT-XX05... 64 G1/2 or NPT
RIZUR-DOT-XX10... 64 G 3/4 or NPT
RIZUR-DOT-XX15... 64 G 3/4 or NP
RIZUR-DOT-XX20... 83 G 3/4 or NPT
RIZUR-DOT-XX25... 89 G1 or NPT
RIZUR-DOT-XX30... 115 G1 1/2 or NPT
RIZUR-DOT-XX35... 133 G2 or NPT

Model H (mm)
Z3/B1 210
Z5 185
Z1 190
M1/M2 118
M4 138

Pulse output (nominal)

Model Pulses/litre    
RIZUR-DOT-XX05... 4000
RIZUR-DOT-XX10... 1700
RIZUR-DOT-XX15... 1100
RIZUR-DOT-XX20... 400
RIZUR-DOT-XX25... 180
RIZUR-DOT-XX30... 60
RIZUR-DOT-XX35... 24
RIZUR-DOT-XX40... 15
RIZUR-DOT-XX45... 6.6
RIZUR-DOT-XX50... 2.3

Thread connection

Model B(mm) С (mm)
RIZUR-DOT-XX05... 64 G1/2 or NPT
RIZUR-DOT-XX10... 64 G 3/4 or NPT
RIZUR-DOT-XX15... 64 G 3/4 or NP
RIZUR-DOT-XX20... 83 G 3/4 or NPT
RIZUR-DOT-XX25... 89 G1 or NPT
RIZUR-DOT-XX30... 115 G1 1/2 or NPT
RIZUR-DOT-XX35... 133 G2 or NPT

Model   H (mm)
Z3/B1 210
Z5 185
Z1 190
M1/M2 118
M4 138

Order code. Thread connection (Example: RIZUR-DOT-1315 N5 F1 В1 0-R)

Housing/connection material Range Mechanical connection * Signal sensor type Electronics Customized options Adapted for use in Russia
DOT-R-13=(stainless steel/stainless steel) 05=0.11-1.1 m3/h G4 = 1/2" male thread

M1***= MS (military style) connector for 120 °C max        

M2***= MS military style) connector for 240 °C max        

M4***= MS (military style) connector preamplifi ed, for 65 °C max    

F1**= Flying leads (compact meter mount, see Electronics) for 120 °C max   

00=Frequency output only

Z1=Electronic module
ZOD-Z1

Z3=Electronic module
ZOD-Z3

Z5=Electronic module
ZOD-Z5

В1=Electronic module
ZOD-B1

0=no
Y=please, specify the chosen position  

 R

10= 0.22-2.2 m3/h

15= 0.4-4.0 m3/h

20 = 0.8-8 m3/h

G5 = 3/4" male thread
25 = 1.6-16 m3/h 
G6 = 1" male thread
30= 3.4-34 m3/h G8 = 1 1/2" male thread
35 = 6.8-68 m3/h G9 = 2" male thread
XX = customized option    XX = customized option    XX = customized option  XX = customized option 

*When using connections NPT RIZUR-DOT-xxxxGx...is changed to RIZUR-DOT-xxxxNx...

** only if installed with electronic modules Z1, Z3, Z5 or В1

*** only when using frequency output "00"

 Order code. Flange connection (Example: RIZUR-DOT-13 50 FE F1 Z3 В-R)

Housing/connection material
Range Mechanical connection* Signal sensor type Electronics Customized options Adapted for use in Russia
Rizur-DOT-13=(stainless steel/ stainless steel) 05=0.11-1.1 m3/h F4* = DN15,PN16

M1***= MS (military style) connector for 120 °C max      

M2***= MS (military style) connector for 240 °C max            

M4***= MS (military style) connector preamplified, for 65 °C max

F1**= Flying leads (compact meter mount, see Electronics) for 120 °C max

00 = Frequency output only

Z1 =Electronic module
ZOD-Z1

Z3=Electronic module
ZOD-Z3

Z5=Electronic module
ZOD-Z5

В1 =Electronic module
ZOD-B1

0=no

B**** = Linearity 0.15% instead of 0.5%

2**** = 2 x pick-offs 90° electrically offset


Y=please, specify the chosen position  

 R

10= 0.22-2.2 m3/h

15= 0.4-4.0 m3/h

20 = 0.8-8 m3/h

F5* = DN20,PN16
25 = 1.6-16 m3/h 

F6*= DN25,PN16

30= 3.4-34 m3/h F8*= DN40,PN16
35 = 6..8-68 m3/h F9*= DN50,PN16
40 = 13.5-135  m3/h FB =DN80,PN16
45 = 27-270 m3/h FC = DN100,PN16
50 = 55-550  m3/h FE = DN150,PN16
 XX = customized options XX = customized options XX = customized options XX = customized options

* is not supplied with Rizur-DOT-12 
** only if installed with electronic modules Z1, Z3, Z5 or В1
*** When using PN25 Change Rizur-DOT-xxxxFx... is changed to...Rizur-DOT-xxxxHx
When using connection ANSI 150 RFRizur-DOT-xxxxFx... is changed to Rizur-DOT-xxxxAx.. or Rizur-DOT-xxxxBx... for ANSI 300RF

****is a part of the supply only when the dimensions are DN100 and above

***** only when using the frequency output "00"

Order code. Thread connection (Example: RIZUR-DOT-1315 N5 F1 В1 0 -R)

Housing/connection material Range Mechanical connection * Signal sensor type Electronics Customized options Adapted for use in Russia
Rizur-DOT-13=(stainless steel/ stainless steel) 05=0.11-1.1 m3/h G4 = 1/2" male thread

M1***= MS (military style) connector for 120 °C max       

M2***= MS (military style) connector for 240 °C max

M4***= MS (military style) connector preamplified, for 65 °C max 

F1**= Flying leads (compact meter mount, see Electronics) for 120 °C max   

00 = Frequency output only

Z1 =Electronic module
ZOD-Z1

Z3=Electronic module
ZOD-Z3

Z5=Electronic module
ZOD-Z5

В1 =Electronic module
ZOD-B1

0=no
Y=please, specify the chosen position  

 R

10= 0.22-2.2 m3/h

15= 0.4-4.0 m3/h

20 = 0.8-8 m3/h

G5 = 3/4" male thread
25 = 1.6-16 m3/h    G6 =1" male thread
30= 3.4-34 m3/h G8 = 1 1/2" male thread
35 = 6..8-68 m3/h     G9 = 2" male thread
 XX = customized option    XX = customized option       XX = customized option   XX = customized option  

* When using connections NPT RIZUR-DOT-xxxxGx... is changed to RIZUR-DOT-xxxxNx...

** only when if installed with electronic modules Z1, Z3, Z5 or В1

*** only when using frequency output "00"

 Order code. Flange connection (Example: DOT-R-13 50 FE F1 Z3 В -R)

Housing/connection material Range Mechanical connection* Signal sensor type Electronics Customized options

Adapted for use in Russia
RIZUR-DOT-13=(stainless steel/ stainless steel) 05=0.11-1.1 m3/h F4* = DN15,PN16

M1***** = MS (military style) connector for 120 °C max

M2***** = MS (military style) connector for 240 °C max

M4***** = MS (military style) connector preamplified, for 65 °C max

F1** = Flying leads (compact meter mount, see Electronics) for 120 °C max 

00 = Frequency output only

Z1 = Electronic module
ZOD-Z1

Z3 = Electronic module
ZOD-Z3

Z5 = Electronic module 
ZOD-Z5

В1 = Electronic module
ZOD-B1

0=no

B**** = Linearity 0.15% instead of 0.5%

2**** = 2 x pick-offs 90° electrically offset


Y=please, specify the chosen position 

 R

10= 0.22-2.2 m3/h

15= 0.4-4.0 m3/h

20 = 0.8-8 m3/h

F5* = DN20,PN16
25 = 1.6-16 m3/h 

F6*= DN25,PN16

30= 3.4-34 m3/h F8*= DN40,PN16
35 = 6..8-68 m3/h F9*= DN50,PN16
40 = 13.5-135  m3/h  FB =DN80,PN16
45 = 27-270 m3/h  FC = DN100,PN16
50 = 55-550  m3/h  FE = DN150,PN16
 XX = customized option XX = customized option XX = customized option XX = customized option

* is not supplied with Rizur-DOT-12 
** only if installed with electronic modules Z1, Z3, Z5 or В1

*** Change DOT-xxxxFx… into DOT-xxxxHx… for PN25

Change DOT-xxxxFx… into DOT-xxxxAx… for ANSI 150 RF connection or into DOT-xxxxBx… for ANSI 300 RF

****only available for sizes DN100 and above

****is a part of the supply only when the dimensions are DN100 and above

*****only when using the frequency output "00"

-XX05... 127
RIZUR-DOT-XX10... 127
RIZUR-DOT-XX15... 127
RIZUR-DOT-XX20... 140
RIZUR-DOT-XX25... 152
RIZUR-DOT-XX30... 178
RIZUR-DOT-XX35... 197
RIZUR-DOT-XX40... 254
RIZUR-DOT-XX45... 356
RIZUR-DOT-XX50... 368
0