Turbine type flow meter RIZUR-DOT
Description
Turbine type flow meter RIZUR-DOT consists of a spiroid turbine rotor, mounted on two tungsten carbide bearings, with the rotor itself, manufactured from hard ferritic stainless steel with a grade compatible with the measured liquid, is positioned fully inside the housing made of non-magnetic stainless steel. The housing has an inductive coil with a magnetic core located in close proximity to the end of the rotor's blades which together with the blades make a magnetic circuit (pic.1).
Rotor's movement changes the magnetic circuit resistance and the changes in the magnetic flow create small voltage in the reel with its frequency directly proportional to the rotor speed and, thus, proportional to the rate of volume flow (flow rate) of the measured liquid
Increase in media viscosity limits the range of the linear flow rate, the lower limit of the flow rate should increase with increase of the liquid’s viscosity with the max. viscosity at 10 mm2/sec. In order to calculate the low level of the linear flow the following should be done: multiply 0.7 by the square root of the measured liquid viscosity in mm²/sec, multiplied by the normal minimum flow rate. For example, if the normal flow range is 10 ~ 100 l/min, then with a viscosity of 5 mm²/s, the minimum flow rate should be 15.65 l/min.
Turbine type flow meter is a high-precision, reliable device that is used for flow measurement of clean liquids with low viscosity. RIZUR-DOT model is manufactured from stainless steel with tungsten carbide bearings ensures long service life for operation with a wide range of aggressive and non-lubricating fluids in the petrochemical industry and general purpose industrial grade usage.
Standard version of the device has a frequency output (mV sinusoidal waves) or a preamplifier output of the square waves (4...20 mA impulses). Turbine type flow meter has a MS terminal for the impulse signal output. It can also be equipped with the integral devices for the operating in adverse conditions that can amplify the signals' transmission range or connect to the accessory instruments that require a corresponding input signal. The devices can be, for example, a Z1 adder, a Z3/Z5 flow integrator or a batch meter B1.
If your flow meter is installed together with some other device, please, use the corresponding manual for information of details and output functions.
Application areas
- Chemicals
- Medical products
- Different types of fuel
- Deionized water
- Fuel additives
Measuring range: | 0.11 - 1.1 m3/h … 13.5 - 135 m3/h for water (other on request) |
Viscosity range: | low viscosity |
Linearity: | ±0.15 % ... ±0.5 % of the readings |
Max. pressure: | 250 bar; |
Max. temperature: | 240 °C |
Process connection: | G ½…G 2 male thread, ½" NP T…2" NPT male thread, DIN-flanges DN 15…DN 150 (larger - on request), ANSI flanges with sizes ½"... 6" (larger - on request) |
Material: | stainless steel, carbon steel |
Output signal: | pulses, LCD display, 4...20mA, batching, totalisi |
Electronic modules with LCD-display
Model |
-Z1 |
.Z3 |
.Z5 |
..В1 |
Function |
dual totaliser |
rate totalizer |
rate totalizer |
batch controller |
Power source |
||||
Battery power |
yes |
yes |
yes |
no |
External power source |
8-24Vdc |
8-24Vdc |
8-24Vdc |
12-24Vdc |
LCD display |
||||
- line 1 /q-ty of digits |
7.5 mm/5 |
9 mm/8 |
17 mm/6 |
9 mm/8 |
- line 2/q-ty of digits |
3.6 mm/8 |
- |
7 mm/8 |
- |
selectable units |
yes |
yes |
yes |
yes |
decimal point |
yes |
yes |
yes |
yes |
subscripts displayed |
yes |
yes |
yes |
yes |
accumulative total |
yes |
yes |
yes |
yes |
resettable total |
yes |
yes |
yes |
no |
linearisation |
no |
yes |
no |
no |
rate display |
no |
yes |
yes |
no |
backlighting |
no |
no |
yes |
no |
Input type |
||||
Battery-powered sensors |
See ZOD technnical specifications table |
|||
Sensors with line supply |
See ZOD technnical specifications table |
|||
Output types |
||||
4-20 mА (750 Ohm) |
no |
yes |
no |
no |
high/low flow alarm |
no |
NPN/PNP |
NPN |
no |
batch end&control |
no |
no |
no |
NPN/PNP |
pulse outputs |
NPN/PNP |
NPN/PNP |
NPN |
NPN/PNP |
2 х SPDT relays |
no |
по заказу* |
no |
по заказу* |
Installation |
|
|||
IP 66/67 |
yes |
yes |
yes |
yes |
cable glands |
1 х cable gland (with intrumentation) 2 х cable glands (at a distance) |
3хМ20 |
3хМ16 |
3хМ20 |
internal protection (optional) |
no | yes | no | no |
mounting |
meter mount, wall, pipe or panel mounting |
|||
temperature range |
-20... +80 °С (Optional: -20... +120 °С) |
*replaces solid state outputs
Flange connection
Model | (mm) |
RIZUR-DOT-XX05... | 127 |
RIZUR-DOT-XX10... |
127 |
RIZUR-DOT-XX15... | 127 |
RIZUR-DOT-XX20... | 140 |
RIZUR-DOT-XX25... | 152 |
RIZUR-DOT-XX30... | 178 |
RIZUR-DOT-XX35... | 197 |
RIZUR-DOT-XX40... | 254 |
RIZUR-DOT-XX45... | 356 |
RIZUR-DOT-XX50... | 368 |
Pulse output (nominal)
Model | Pulses/litre |
RIZUR-DOT-XX05... | 4000 |
RIZUR-DOT-XX10... | 1700 |
RIZUR-DOT-XX15... | 1100 |
RIZUR-DOT-XX20... | 400 |
RIZUR-DOT-XX25... | 180 |
RIZUR-DOT-XX30... | 60 |
RIZUR-DOT-XX35... | 24 |
RIZUR-DOT-XX40... | 15 |
RIZUR-DOT-XX45... | 6.6 |
RIZUR-DOT-XX50... | 2.3 |
Thread connection
Model | B(mm) | С (mm) |
RIZUR-DOT-XX05... | 64 | G1/2 or NPT |
RIZUR-DOT-XX10... | 64 | G 3/4 or NPT |
RIZUR-DOT-XX15... | 64 | G 3/4 or NP |
RIZUR-DOT-XX20... | 83 | G 3/4 or NPT |
RIZUR-DOT-XX25... | 89 | G1 or NPT |
RIZUR-DOT-XX30... | 115 | G1 1/2 or NPT |
RIZUR-DOT-XX35... | 133 | G2 or NPT |
Model | H (mm) |
Z3/B1 | 210 |
Z5 | 185 |
Z1 | 190 |
M1/M2 | 118 |
M4 | 138 |
Pulse output (nominal)
Model | Pulses/litre |
RIZUR-DOT-XX05... | 4000 |
RIZUR-DOT-XX10... | 1700 |
RIZUR-DOT-XX15... | 1100 |
RIZUR-DOT-XX20... | 400 |
RIZUR-DOT-XX25... | 180 |
RIZUR-DOT-XX30... | 60 |
RIZUR-DOT-XX35... | 24 |
RIZUR-DOT-XX40... | 15 |
RIZUR-DOT-XX45... | 6.6 |
RIZUR-DOT-XX50... | 2.3 |
Thread connection
Model | B(mm) | С (mm) |
RIZUR-DOT-XX05... | 64 | G1/2 or NPT |
RIZUR-DOT-XX10... | 64 | G 3/4 or NPT |
RIZUR-DOT-XX15... | 64 | G 3/4 or NP |
RIZUR-DOT-XX20... | 83 | G 3/4 or NPT |
RIZUR-DOT-XX25... | 89 | G1 or NPT |
RIZUR-DOT-XX30... | 115 | G1 1/2 or NPT |
RIZUR-DOT-XX35... | 133 | G2 or NPT |
Model | H (mm) |
Z3/B1 | 210 |
Z5 | 185 |
Z1 | 190 |
M1/M2 | 118 |
M4 | 138 |
Order code. Thread connection (Example: RIZUR-DOT-1315 N5 F1 В1 0-R)
Housing/connection material | Range | Mechanical connection * | Signal sensor type | Electronics | Customized options | Adapted for use in Russia |
DOT-R-13=(stainless steel/stainless steel) | 05=0.11-1.1 m3/h | G4 = 1/2" male thread |
M1***= MS (military style) connector for 120 °C max M2***= MS military style) connector for 240 °C max M4***= MS (military style) connector preamplifi ed, for 65 °C max F1**= Flying leads (compact meter mount, see Electronics) for 120 °C max |
00=Frequency output only
Z1=Electronic module
Z3=Electronic module
Z5=Electronic module
В1=Electronic module |
0=no |
R |
10= 0.22-2.2 m3/h 15= 0.4-4.0 m3/h 20 = 0.8-8 m3/h |
G5 = 3/4" male thread | |||||
25 = 1.6-16 m3/h |
G6 = 1" male thread
|
|||||
30= 3.4-34 m3/h | G8 = 1 1/2" male thread | |||||
35 = 6.8-68 m3/h | G9 = 2" male thread | |||||
XX = customized option | XX = customized option | XX = customized option | XX = customized option |
*When using connections NPT RIZUR-DOT-xxxxGx...is changed to RIZUR-DOT-xxxxNx...
** only if installed with electronic modules Z1, Z3, Z5 or В1
*** only when using frequency output "00"
Order code. Flange connection (Example: RIZUR-DOT-13 50 FE F1 Z3 В-R)
Housing/connection material |
Range | Mechanical connection* | Signal sensor type | Electronics | Customized options | Adapted for use in Russia |
Rizur-DOT-13=(stainless steel/ stainless steel) | 05=0.11-1.1 m3/h | F4* = DN15,PN16 |
M1***= MS (military style) connector for 120 °C max M2***= MS (military style) connector for 240 °C max M4***= MS (military style) connector preamplified, for 65 °C max F1**= Flying leads (compact meter mount, see Electronics) for 120 °C max |
00 = Frequency output only
Z1 =Electronic module
Z3=Electronic module
Z5=Electronic module
В1 =Electronic module |
0=no B**** = Linearity 0.15% instead of 0.5% 2**** = 2 x pick-offs 90° electrically offset
|
R |
10= 0.22-2.2 m3/h 15= 0.4-4.0 m3/h 20 = 0.8-8 m3/h |
F5* = DN20,PN16 | |||||
25 = 1.6-16 m3/h |
F6*= DN25,PN16 |
|||||
30= 3.4-34 m3/h | F8*= DN40,PN16 | |||||
35 = 6..8-68 m3/h | F9*= DN50,PN16 | |||||
40 = 13.5-135 m3/h | FB =DN80,PN16 | |||||
45 = 27-270 m3/h | FC = DN100,PN16 | |||||
50 = 55-550 m3/h | FE = DN150,PN16 | |||||
XX = customized options | XX = customized options | XX = customized options | XX = customized options |
* is not supplied with Rizur-DOT-12
** only if installed with electronic modules Z1, Z3, Z5 or В1
*** When using PN25 Change Rizur-DOT-xxxxFx... is changed to...Rizur-DOT-xxxxHx
When using connection ANSI 150 RFRizur-DOT-xxxxFx... is changed to Rizur-DOT-xxxxAx.. or Rizur-DOT-xxxxBx... for ANSI 300RF
****is a part of the supply only when the dimensions are DN100 and above
***** only when using the frequency output "00"
Order code. Thread connection (Example: RIZUR-DOT-1315 N5 F1 В1 0 -R)
Housing/connection material | Range | Mechanical connection * | Signal sensor type | Electronics | Customized options | Adapted for use in Russia |
Rizur-DOT-13=(stainless steel/ stainless steel) | 05=0.11-1.1 m3/h | G4 = 1/2" male thread |
M1***= MS (military style) connector for 120 °C max M2***= MS (military style) connector for 240 °C max M4***= MS (military style) connector preamplified, for 65 °C max F1**= Flying leads (compact meter mount, see Electronics) for 120 °C max |
00 = Frequency output only
Z1 =Electronic module
Z3=Electronic module
Z5=Electronic module
В1 =Electronic module |
0=no |
R |
10= 0.22-2.2 m3/h 15= 0.4-4.0 m3/h 20 = 0.8-8 m3/h |
G5 = 3/4" male thread | |||||
25 = 1.6-16 m3/h | G6 =1" male thread | |||||
30= 3.4-34 m3/h | G8 = 1 1/2" male thread | |||||
35 = 6..8-68 m3/h |
G9 = 2" male thread |
|||||
XX = customized option | XX = customized option | XX = customized option | XX = customized option |
* When using connections NPT RIZUR-DOT-xxxxGx... is changed to RIZUR-DOT-xxxxNx...
** only when if installed with electronic modules Z1, Z3, Z5 or В1
*** only when using frequency output "00"
Order code. Flange connection (Example: DOT-R-13 50 FE F1 Z3 В -R)
Housing/connection material | Range | Mechanical connection* | Signal sensor type | Electronics |
Customized options |
Adapted for use in Russia |
RIZUR-DOT-13=(stainless steel/ stainless steel) | 05=0.11-1.1 m3/h | F4* = DN15,PN16 |
M1***** = MS (military style) connector for 120 °C max M2***** = MS (military style) connector for 240 °C max M4***** = MS (military style) connector preamplified, for 65 °C max F1** = Flying leads (compact meter mount, see Electronics) for 120 °C max |
00 = Frequency output only
Z1 = Electronic module
Z3 = Electronic module
Z5 = Electronic module
В1 = Electronic module |
0=no B**** = Linearity 0.15% instead of 0.5% 2**** = 2 x pick-offs 90° electrically offset
|
R |
10= 0.22-2.2 m3/h 15= 0.4-4.0 m3/h 20 = 0.8-8 m3/h |
F5* = DN20,PN16 | |||||
25 = 1.6-16 m3/h |
F6*= DN25,PN16 |
|||||
30= 3.4-34 m3/h | F8*= DN40,PN16 | |||||
35 = 6..8-68 m3/h | F9*= DN50,PN16 | |||||
40 = 13.5-135 m3/h | FB =DN80,PN16 | |||||
45 = 27-270 m3/h | FC = DN100,PN16 | |||||
50 = 55-550 m3/h | FE = DN150,PN16 | |||||
XX = customized option | XX = customized option | XX = customized option | XX = customized option |
* is not supplied with Rizur-DOT-12
** only if installed with electronic modules Z1, Z3, Z5 or В1
*** Change DOT-xxxxFx… into DOT-xxxxHx… for PN25
Change DOT-xxxxFx… into DOT-xxxxAx… for ANSI 150 RF connection or into DOT-xxxxBx… for ANSI 300 RF
****only available for sizes DN100 and above
****is a part of the supply only when the dimensions are DN100 and above
*****only when using the frequency output "00"
-XX05... | 127 |
RIZUR-DOT-XX10... | 127 |
RIZUR-DOT-XX15... | 127 |
RIZUR-DOT-XX20... | 140 |
RIZUR-DOT-XX25... | 152 |
RIZUR-DOT-XX30... | 178 |
RIZUR-DOT-XX35... | 197 |
RIZUR-DOT-XX40... | 254 |
RIZUR-DOT-XX45... | 356 |
RIZUR-DOT-XX50... | 368 |