Explosion-proof heaters RIZUR-OShA-R

Heaters "OShA-R" are designed for use mainly in petroleum and gas industry in hazardous areas of inside and outside facilities of V-1a and V-1d (acc. to PUE ch. 7.3) for heating enclosures and boxes with EC&I and equipment that requires positive temperature for normal operation.



Explosion-proof heaters RIZUR-OShA-R have six design variants:

F - variant– equipped with a bimetallic thermostat (thermoregulator). All electric elements are placed in a metal housing and the jacket cavities are filled with heat-resistant heatconductive compound. The heater in F-variant is supplied with a power cable. The length of the power cable is specified at the time of order (standard length - 1m). This design variant does not allow for changes in temperature settings.  

FT - variant - equipped with a bimetallic thermostat (thermoregulator) and RIZUR-KC junction box.

S-variant - equipped with intelligent digital control module. At the software level, the heater is controlled by Jack E. Bresenham's modified adaptive algorithm. This algorithm ensures smooth long-time control of the heater's capacity and allows to maintain ambient air temperature in the heated area within an accuracy of 1°С. Surface temperature is in the range of  +20º ... +90ºС, the temperature inside the enclosure +1…+49 ºС. These paramters are chosen on the basis of the inquiry form. It's supplied with the supply cable, length of which is chosen at the order time.

ST-variant - equipped with intelligent digital control module and RIZUR-KC junction box. At the software level, the heater is controlled by Jack E. Bresenham's modified adaptive algorithm. This algorithm ensures smooth long-time control of the heater's capacity and allows to maintain ambient air temperature in the heated area within an accuracy of 1°С. Surface temperature is in the range of  +20º ... +90ºС, the temperature inside the enclosure +1…+49 ºС. These paramters are chosen on the basis of the inquiry form. This design varinat allows to power the heater using the junction box that is ibn the scope of supply.

SR-variant - equipped with intelligent digital control module. This heater is used with the thermoregulator RIZUR-TB-DCS manufactured on the basis of the digital control system consisting of a microcontroller, operating under the software, and a remote digital temperature sensor with the possibility of emergency signalling (relay output, 4...20mA, etc.). Additionally, specify the order code for the thermoregulator RIZUR-TB-DCS.

AR-variant - equipped with a built-in thermoregulator RIZUR-TB-DCS-2. This design variant is an intellligent heating system because it allows to control remotely climate conditions in the heater's location using PC or RS 485. Such addition allows to take readings of inside temperature, heater's temperature, correctness of the equipment operation, power consumed. This variant of the heater on the basis of a digital control system with local and remote control and emergency alarm setting. Additionally, specify the order code for the thermoregulator RIZUR-TB-DCS-2.


osha_CSU-2.jpg
osha_CSU.jpg

Electric explosion-proof heaters are successfully used at:

  • Explosion-hazardous spaces
  • Enclosures for EC&I (Diabox, КШО, insulated enclosures, EC&I enclosures, control automation cabinets, DIABOXes, thermoboxes, MultiBoxes)
  • Gas-distribution plants (cabinet-type gas control point, package type gas distribution unit, individual pressure regulating station, gas-distribution plant with gas heating)
  • Oil metering points, gas flow metering points
  • Drill man’s cabin
  • Tower cranes
  • Everyday life: garages, houses, bathrooms, and other spaces
  • Other variants:
                   - heaters for enclosures 
                   - heaters for control cabinets 
                   - explosion-proof heaters 

Technical characteristics

Installation area General industrial areas
Explosion hazard zones V-1а and V-1g acc. to Electrical installation code (PUE), Ch. 7.3
Explosion-proof marking 1 Ex mb IIC (T3…T6) Gb X
Heating element power 40 ... 2000 W
Power supply voltage 220 (±15%) V
24, 36-48 V AC/DC (upon an agreement with the manufacturer)
Temperature on the heater’s surface +90…+100°C (for design variants F, FT)
-30…+90°C, an increment of 1°C (for design variants S, ST, SR, AR)
Temperature maintained +10…+20°C (for design variants F, FT)
-40…+50°C, an increment of 1°C (for design variants S, ST, SR, AR)
Ingress protection IP54 acc.to GOST 14254-96
IP66, IP67 (upon an ahreement with the manufacturer) acc. to GOST 14254-96
Insulation strength min.1500 V
Insulation resistance min. 20 MOhm
Protection against electrical shock  class 1 acc. to GOST 12.2.007.0
Preset temperature limit alarm relay, "dry" contact, break-before-make (for design variants SR, AR)
Warranty period 24 months
Average operation time
over 10 years

Connection dimensions
Mounting on a vertical surface
Design variant
Dimensions, mm
А В С RizurOShA-R.png
OShA-R-1 218…226 (248) -(-) 44 (15)
OShA-R-2 218…226 (248) -103 44 (15)
OShA-R-3 218…226 (248) -203 44 (15)
OShA-R-4 318…326 (348) -204 44 (15)
OShA-R-10 518…526 (548) 345 (303) 44 (15)
OShA-R-15 718…726 (748) 346 (303) 44 (15)
OShA-R-20 718…726 (748) 445 (403) 44 (15)
Mounting on a vertical surface
OShA-R-1 218…226 (248) - 44 (15)
OShA-R-2 218…226 (248) - 44 (15)
OShA-R-3 218…226 (248) - 44 (15)
OShA-R-4 318…326 (348) - 44 (15)
OShA-R-10 518…526 (548) - 44 (15)
OShA-R-15 718…726 (748) - 44 (15)
OShA-R-20 718…726 (748) - 44 (15)

Model Drawing
OSha-R-1
OSha-R-2
OSha-R-3
OSha-R-4
OSha-R-10
OSha-R-15
OSha-R-20